  1 2 3 6 5 4  model number designation p s 6 - 1 0 2 v - n a r series name pressure port output switch output interface rated pressure range pressure reference 102  100 kpa 103  1000 kpa g  gauge v  gauge (vacuum) r  r1/8 male screw with m5 female screw m  m5 female screw a  1 sw output and adjustable hysteresis + analog output w  2 sw outputs n  npn open collector p  pnp open collector pressure switches with gauge ps6 1 2 3 4 5 6 part name material pressure port housing o ring sensor module board protection panel main panel pom (polyoxymethylene) pc (polycarbonate) fluoro-rubber pet (polyethyleneterephthalate) internal structure (m5 female screw)  solidstate pressure switch with no mechanical moving parts  2 types of pressure ports are available  open collector output of either npn or pnp is available  analog output type available  features  list of model numbers pressure port r 1/8 male screw m 5 female screw outputs adjustable hysteresis switch output + analog output npn open collector output pnp open collector output npn open collector output pnp open collector output npn open collector output pnp open collector output npn open collector output pnp open collector output switch outputs (2 points) adjustable hysteresis switch output + analog output switch outputs (2 points) switch output 102v 102g 103g 0 ~ ? 100 kpa 0 ~ 100 kpa 0 ~ 1000 kpa yyy ps6-102v-nar yyy yyy ps6-102g-nar yyy yy ps6-103g-nar yyy ps6-102v-par yyyyyy PS6-102G-PAR y ps6-103g-par yyy ps6-102v-nwr yy yyy ps6-102g-nwr y  ps6-103g-nwr yyy ps6-102v-pwr yyy yyy ps6-102g-pwr y  ps6-103g-pwr yyy ps6-102v-nam yyy yyy ps6-102g-nam  ps6-103g-nam yyy ps6-102v-pam yyy yyy ps6-102g-pam y  ps6-103g-pam yyy ps6-102v-nwm yy yyyy ps6-102g-nwm y  ps6-103g-nwm yyy ps6-102v-pwm yy yyyy ps6-102g-pwm y  ps6-103g-pwm t verify the above model numbers when placing orders. marking compatible with em c directive
ps6 pressure switches with gauge general specifications display power item model number ps6 102v 102g 103g  standard spe c ifi c ations pressure reference gauge non-corrosive gases 0 ~ ? 100 0 ~ 100 0 ~ 1000 200 200 1500 500 500 2000 ? 10 ~ 60 0 ~ 50 35 ~ 85  no condensation  ? 20 ~ 70  atmospheric pressure, humidity 65 %rh maximum  approx.   including cable  12 ~ 24 v 10 %  including ripple percentage  35 100 (500 v dc) 500 v ac, 60 s  leakage current 1 ma maximum  r 1/8 . female screw  or . 2-digit led ? 0 ~ ? 99 kpa 0 ~ 99 kpa .0 ~ .99 mpa 3 %f.s. 2counts 1 count pressure medium rated pressure range kpa maximum pressure kpa break-down pressure kpa operating temp. range c compensated temp. range c operating humidity %rh storage temp. c net weight g supply voltage v dc consumption current ma max. insulation resistance m min. dielectric strength pressure port display element rated display range display accuracy  ? ?  reference temp. 25 c  resolution  unless otherwise specified, the specs are defined at an ambient temperature of 25 5 c and excitation voltage of 12 v dc. switch output analog output approx. 0 ~ 15 % of the set value (w type only 2 % f.s. maximum) 30 v 80 ma maximum 0.8 (npn), 1.2 (pnp) 0 ~ 100 of rated pressure t t red led on (w type only : sw1 red, sw2 green) 3 approx. 2 1 ~ 5 1 0.1 4 0.1  load resistance 5 k minmum  adjustable range switching capacity residual voltage v maximum display accuracy  ? ?  '4  reference temp. 25 c  switch hysteresis response ms output voltage v zero voltage v span voltage v output current ma maximum t please set adjusting torque at 30 mnm maximum. t the actual setting range adjustable by vr has a little overrunning margin beyond the rated display of 0 through 99. this could cause the setting value of vr may be under 0 or over 99. open collector output (npn or pnp) adjustable by vr 1 or 2 no. of outputs output interface setting method
off hysteresis set value hysteresis set value  100 kpa rated pressure barometic pressure barometic pressure on off on fg led pressure indication a.output !y indicator 1 common sensor power b main circuit s.output load pressure fg led pressure indication a.output common s.output power b load pressure main circuit sensor !y indicator 1 fg 1 !y indicator 2 load s.output2 common sensor power b main circuit s.output1 load pressure fg 2 !y indicator 1 common s.output2 power b load load pressure main circuit sensor s.output1  nam, nar (npn/a d jus table h ys tere s i s s witch )  ps6-102v  ps6- ??? g  pam, par (pnp/a d jus table h ys tere s i s s witch ) ps6 pressure switches with gauge  c ir c uit diagrams  environmental c hara c teristi c s test item test conditions permissible change vibration 10 ~ 500 hz, 1.5 mm maximum/98.1 m/s 2 , 3 directions for 2 hours each 196 m/s 2 , 3 directions for 3 times each 40 c, 90 ~ 95 %rh, 240 hrs. 0 ~ rated pressure, 10 6 cycles emi : en55011: 2007, a2 : 2007 group 1, class b  ems : en61326-1 : 2006 table 2 pressure indication, switch operating pressure and analog output variation : 2 %f.s., maximum each after test pressure indication, switch operating pressure and analog output variation : 5 %f.s., maximum during test shock moisture resistance pressure cycling emc  swit c hing operation ? the switch turns on at the set pressure and turns off at the set pressure minus the hysteresis. t ? a ? is adjustable hysteresis type.  nwm, nwr (npn/2 s witch o u tp u t s)  pwm, pwr (pnp/2 s witch o u tp u t s)
 outline dimentions unless otherwise specified, tolerance : 0.5 (unit: mm) ps6 pressure switches with gauge polyacetal polycarbonate mounting hole 2 C 3.3 4-core shielded cable l = 1500 50 awg26 ulno.2844 ( 3.8) 52.5 25 12 8.5 4.5 r1/8 10 pressure port m5 depth 5 hysteresis setting vr t used to set the switch 2 for two-switch output model recommended adjusting torque 30 mnm maximum display selector switch (me/sw) t for two-output switch (me/s1/s2) recommended adjusting torque 25 mnm maximum switch status led 1 (red) switch status led 2 (green) t only for two-switch output model pressure indication pressure setting vr t used to set the switch 1 for two-output type recommended adjusting torque 30 mnm maximum polyacetal polycarbonate mounting hole 2 C 3.3 52.5 25 12 4.5 19 10 5 pressure port m5 depth  2 C m3 depth 4.5 pressure indication switch status led 1 (red) switch status led 2 (green) t only for two-switch output model display selector switch (me/sw) t for two-output switch (me/s1/s2) recommended adjusting torque 25 mnm maximum hysteresis setting vr t used to set the switch 2 for two-switch output model recommended adjusting torque 30 mnm maximum pressure setting vr t used to set the switch 1 for two-switch output model recommended adjusting torque 30 mnm maximum 4-core shielded cable l = 1500 50 awg26 ulno.2844 ( 3.8)  r t y pe (nar, par, nwr, pwr)  m t y pe (nam, pam, nwm, pwm) wire color brown black white blue shield connection power b switch output analog output common n.c. ps6 (nam,nar, pam, par) wire color brown black white blue shield connection power b switch output 1 switch output 2 common n.c. ps6 (nwm, nwr, pwm, pwr)


▲Up To Search▲   

 
Price & Availability of PS6-102G-PAR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X